Difference between revisions of "Extended USRP Environmental"

From Ettus Knowledge Base
Jump to: navigation, search
m (→‎Shock and Vibration Qualification)
m (→‎Application Note Number and Authors)
 
Line 9: Line 9:
 
== <span style="font-family:Cambria, Georgia, serif; font-size:20pt; font-weight:normal; color:#008958;">Application Note Number and Authors</span> ==
 
== <span style="font-family:Cambria, Georgia, serif; font-size:20pt; font-weight:normal; color:#008958;">Application Note Number and Authors</span> ==
  
−
AN-966 by Daniel Wen, Kambrey Marini
+
AN-966 by Daniel Wen, Kambrey Marini, Cole Garrison
  
 
This document presents the results of extended environmental research on the Ettus USRP B210, B206mini-I, OBX-160 installed in the X310, and X420. The research examines RF performance beyond the official operating temperature specifications, including cold-start functionality, high-temperature stress testing, and transmit frequency accuracy. It also documents exploratory shock and vibration research conducted on the B210, B206mini-I, and OBX-160 installed in the X310, none of which had previously been tested for ruggedness.
 
This document presents the results of extended environmental research on the Ettus USRP B210, B206mini-I, OBX-160 installed in the X310, and X420. The research examines RF performance beyond the official operating temperature specifications, including cold-start functionality, high-temperature stress testing, and transmit frequency accuracy. It also documents exploratory shock and vibration research conducted on the B210, B206mini-I, and OBX-160 installed in the X310, none of which had previously been tested for ruggedness.

Latest revision as of 15:35, 20 November 2026

Ettus USRP Extended Environmental Research Knowledge Base

Application Note Number and Authors

AN-966 by Daniel Wen, Kambrey Marini, Cole Garrison

This document presents the results of extended environmental research on the Ettus USRP B210, B206mini-I, OBX-160 installed in the X310, and X420. The research examines RF performance beyond the official operating temperature specifications, including cold-start functionality, high-temperature stress testing, and transmit frequency accuracy. It also documents exploratory shock and vibration research conducted on the B210, B206mini-I, and OBX-160 installed in the X310, none of which had previously been tested for ruggedness.

Disclaimer

This document summarizes the results of extended environmental research performed on a limited, non-statistical number of units of Ettus USRP products. The testing was conducted as an engineering research effort to better understand observed device behavior beyond published operating specifications and under the specific conditions described in this document. It is not intended to establish new product specifications, environmental ratings, or guaranteed operating limits. Official product datasheets remain the authoritative source for verified operating conditions and product specifications.

Testing was designed around common customer transmit and receive use cases and focused on verification of core RF functionality under the documented environmental conditions. Validation of all device interfaces, peripheral functions, accessories, and operating modes was outside the scope of this extended research effort. As such, successful test completion should be interpreted as verification of the tested RF functionality only.

Successful completion of the tests described in this document should not be interpreted as evidence of long-term reliability, lifetime performance, or component aging effects. Several evaluations were designed to assess functionality and short-duration operational stability only, including elevated-temperature testing conducted for approximately 30 minutes at each test condition.

RF Performance Over Temperature

Cold Start Testing

Objective

Cold-start testing was conducted to characterize device startup behavior after extended exposure to low temperatures. The purpose of this evaluation was to identify potential temperature-related limitations affecting device initialization, subsystem startup, and immediate RF operation following power application. For the purposes of this research, successful initialization and verification of a Tx/Rx loopback test were considered successful cold-start functionality.

Test Procedure

  1. Cold Soak the DUT until board reaches steady state at target ambient temperature
  2. Power on the DUT and verify initialization running the uhd_find_devices and uhd_usrp_probe command
  3. Execute a Tx/Rx Loopback test
  4. Verify basic RF functionality by adjusting Rx and Tx gain settings and confirming corresponding changes in received signal power

Scope & Considerations

B210: The B210 has a published operating temperature range of 0°C to 45°C. Cold-start testing was conducted at -40°C using the board-only configuration, representing operation 40°C below the published minimum operating temperature.

B206Mini-I: The B206mini-I board-only configuration has a published operating temperature range of 0°C to 45°C. Cold-start testing was conducted at -40°C using the board-only configuration. The enclosed variant is separately, officially specified for operation from -40°C to 75°C. The cold start testing results are consistent with the official enclosed specifications; however, they should not be interpreted as official specifications for the board only variant.

X310+OBX: The OBX-160 installed in the X310 has a published operating temperature range of 0°C to 40°C. Cold-start testing was performed at -40°C, representing operation significantly below the published specifications

X420: The X420 has a published operating temperature range of 0°C to 50°C. Cold-start testing was performed at -40°C, representing operation significantly below the published specifications

B210

Device Configuration

Table 1: B210 Cold-Start Test Parameters
Parameter Value
Hardware Configuration Board Only
RF Operation Tx/Rx Loopback (Both Channels)
Center Frequency 1 GHz
Sample Rate 10 MS/s
Tx Gain 40dB
Rx Gain 40dB
External Attenuation 60dB
Waveform Type CW Tone

Results

Table 2: B210 Cold-Start Results
DUT Ambient Temperature (°C) Result
B210 1 -40 Observed Functional Operation
B210 2 -40 Observed Functional Operation

B206Mini-I

Device Configuration

Table 3: B206mini-I Cold-Start Test Configuration
Parameter Value
Hardware Configuration Board Only
RF Operation Tx/Rx Loopback
Center Frequency 1 GHz
Sample Rate 10 MS/s
Tx Gain 40dB
Rx Gain 40dB
External Attenuation 60dB
Waveform Type CW Tone

Results

Table 4: B206mini-I Cold-Start Results
DUT Ambient Temperature (°C) Result
B206Mini-I 1 -40 Observed Functional Operation
B206Mini-I 2 -40 Observed Functional Operation

X310 with OBX-160 Installed

Device Configuration

Table 5: OBX-160 Installed in X310 Cold-Start Test Configuration
Parameter Value
RF Operation Tx/Rx Loopback (Both Channels)
Center Frequency 1 GHz
Sample Rate 10 MS/s
Tx Gain 20dB
Rx Gain 20dB
External Attenuation 60dB
Waveform Type CW Tone

Results

Table 6: OBX-160 Installed in X310 Cold-Start Results
DUT Ambient Temperature (°C) Result
X310+OBX 1 -40 Observed Functional Operation
X310+OBX 2 -40 Observed Functional Operation

X420

Device Configuration

Table 7: X420 Cold-Start Test Configuration
Parameter Value
RF Operation Tx/Rx Loopback (Both Channels)
Center Frequency 5 GHz
Sample Rate 50 MS/s
Tx Gain 60dB
Rx Gain 10dB
External Attenuation 60dB
Waveform Type CW Tone

Results

Table 8: X420 Cold-Start Results
DUT Ambient Temp(°C) Recorded DB Temp (°C) Recorded FPGA Temp (°C) Result
X420 Unit 1 -40 Not Recorded Not Recorded No Functional Operation Observed
X420 Unit 1 -10 -5 0 Observed Functional Operation

Note: The temperatures shown for passing tests are the lowest temperatures at which the device successfully started and operated. Failed tests did not record a recovery temperature.

High Temperature Stress Testing

Objective

High temperature stress testing was conducted to characterize device functionality and operational stability at elevated ambient temperatures. The purpose of this evaluation was to identify potential temperature-related limitations affecting RF operation, device initialization, thermal management, and overall system stability when exposed to temperatures beyond published operating specifications.

Test Procedure

  1. Set chamber to the target ambient temperature and let board reach steady state
  2. Power on the DUT and verify initialization running the uhd_find_devices and uhd_usrp_probe command
  3. Verify stable operation for 0.5 Hrs. with no streaming errors, device resets, or thermal shutdown events

Scope & Considerations

High temperature stress testing was designed to evaluate functionality and short-duration operational stability under elevated ambient temperatures. Each test condition consisted of approximately 30 minutes of operation after thermal stabilization. These results do not evaluate long-term effects of the device. Successful operation during this testing characterizes the tested units and should not be interpreted as evidence of sustained performance at elevated temperatures.

FPGA Temperature Measurements: Recorded FPGA temperatures are included as an indicator of the thermal conditions experienced by the device during testing. These values provide additional context beyond ambient chamber temperature and help illustrate the thermal margin available to the FPGA under the documented test conditions. FPGA temperatures were not used as a pass/fail criterion but are provided as supplemental thermal characterization data.

B210: The B210 board-only and enclosed configurations have a published operating temperature range of 0°C to 45°C. High-temperature stress testing was conducted up to 70°C, representing operation 25°C above the published maximum operating temperature.

B206Mini-I: The B206mini-I board-only configuration has a published operating temperature range of 0°C to 45°C. High temperature testing was conducted up to 70°C for both device variants. The enclosed variant is separately, officially specified for operation from -40°C to 75°C. The board only testing results are consistent with the official enclosed specifications; however, they should not be interpreted as official specifications for the board only variant.

X310+OBX: The OBX-160 installed in the X310 has a published operating temperature range of 0°C to 40°C. High temperature testing was performed up to 70°C.

X420: The X420 has a published operating temperature range of 0°C to 50°C. High temperature testing was performed up to 70°C.

B210

Device Configuration

Table 9: B210 High-Temperature Stress Test Configuration
Parameter Tx Rx
Center Frequency 5 GHz 5 GHz
Sampling Rate 10 MS/s 20 MS/s
Gain 30dB 76dB
External Attenuation 30dB 30dB

Results

Table 10: B210 High-Temperature Stress Test Results
Unit Ambient Temperature (°C) Recorded FPGA Temperature (°C) Result
Board Only 70 Not Recorded Observed Functional Operation
Normal Enclosure 70 88 Observed Functional Operation

B206Mini-I

Device Configuration

Table 11: B206mini-I High-Temperature Stress Test Configuration
Parameter Tx Rx
Center Frequency 5 GHz 5 GHz
Sampling Rate 10 MS/s 20 MS/s
Gain 30dB 76dB
External Attenuation 30dB 30dB

Results

Table 12: B206mini-I High-Temperature Stress Test Results
Unit Ambient Temperature (°C) Recorded FPGA Temperature (°C) Result
B206mini-I Board Only 70 Not Recorded Observed Functional Operation
B206mini-I Enclosed 70 84 Observed Functional Operation

X310 with OBX-160 Installed

Device Configuration

Table 13: OBX-160 Installed in X310 High-Temperature Stress Test Configuration
Parameter Tx Rx
Center Frequency 5 GHz 5 GHz
Sampling Rate 50 MS/s 200 MS/s
Gain 25dB 10dB
External Attenuation 30dB 30dB

Results

Table 14: OBX-160 Installed in X310 High-Temperature Stress Test Results
Unit Ambient Temperature (°C) Recorded FPGA Temperature (°C) Result
X310+OBX 1 70 90.8 Observed Functional Operation
X310+OBX 2 70 92.7 Observed Functional Operation

X420

Device Configuration

Table 15: X420 High-Temperature Stress Test Configuration
Parameter Tx Rx
Center Frequency 5 GHz 5 GHz
Sampling Rate 491.52 MS/s 491.52 MS/s
Gain 60dB 10dB
External Attenuation 30dB 30dB

Note: High-temperature stress testing was performed with the default (exhaust airflow) fan configuration. Results may differ if the alternative intake airflow configuration is used.

Results

Table 16: X420 High-Temperature Stress Test Results
DUT Ambient Temp (°C) Recorded FPGA Temp (°C) Recorded DB Temp (°C) Result
X420 Unit 1 70 Not Recorded Not Recorded No Functional Operation Observed
X420 Unit 1 60 74 73 Observed Functional Operation

Note: Recoded temperatures represent the highest observed temperatures at which the device successfully passed.

Tx Frequency Accuracy

Objective

Transmit frequency accuracy testing was conducted to characterize the startup frequency error of each device across the evaluated temperature range. The objective was to identify temperature-dependent frequency deviations immediately following initialization and to provide insight into the observed frequency stability of the tested units under the documented conditions. Frequency error was evaluated across representative frequencies for each platform and reported in parts per million (ppm)

[math]Frequency\ Error\ (ppm) = \frac{f_{measured} - f_{expected}}{f_{expected}} \times 10^{6}[/math]

Test Procedure

  1. Set chamber to the target ambient temperature and let board reach steady state
  2. Power on the DUT and verify initialization running the uhd_find_devices and uhd_usrp_probe command
  3. Run Tx Frequency Accuracy Sweep

Scope & Considerations

Startup Frequency Error: Frequency accuracy measurements were intentionally performed immediately following device initialization at each temperature setpoint. This approach provided a consistent methodology for evaluating frequency errors across the full temperature range and allowed direct comparison between test conditions. Because measurements were taken immediately following initialization, the reported frequency errors represent startup behavior rather than steady-state operation. Additional warm-up time, particularly at colder temperatures, may improve frequency accuracy.

Reference Clock Configuration: Frequency accuracy measurements were performed using independent reference clocks for the DUT and measurement equipment. This approach reflects a standalone operating condition and prevents shared reference clocks form influencing measured startup frequency error. In many applications, a common external reference clock may be used between systems, which can further improve frequency accuracy. The RFSA was configured to use the PXI clock during testing. To verify the selected measurement reference did not materially affect the results, spot-check validations were performed using the onboard reference clock of a PXIe-5842. No significant impact on the measured frequency error or frequency drift over temperature was observed.

Measurement Resolution and Reported Precision: Frequency error values were derived from frequency offset measurements with an effective resolution of approximately 1 kHz. The equivalent ppm resolution varies with carrier frequency, ranging from approximately 1 ppm at 1 GHz to approximately 0.05 ppm at 20 GHz. Reported values have been rounded to reflect the practical resolution limits of the measurement system to avoid implying greater precision than was achievable. Actual device performance may be better than indicated by reported values.

B210

Device Configuration

Table 17: B210 Transmit Frequency Accuracy Test Configuration
Settings RFSA SDR – B210
Hardware Configuration -- Board Only
Frequency Range 1 – 6 GHz 1 – 6 GHz
Ref Clock PXI Clock* Internal
Clock Rate 10 MS/s 61.44 MS/s

*Note: Results were also verified with VST Onboard Clock and had no significant impact on the frequency accuracy drift over temperature.

Results

Table 18: B210 Transmit Frequency Error over Temperature — Unit 1
Ambient Temperature (°C) 1 GHz (ppm) 3 GHz (ppm) 6 GHz (ppm)
-40 4 3.7 3.7
-30 4 4 4
-20 3 2.7 2.8
-10 3 2.7 2.5
0 2 2.3 2.3
10 2 2.3 2.3
20 2 2.3 2.3
30 2 2 2.2
40 2 2.3 2.2
50 2 2.3 2.2
60 2 2 2
70 2 2 2
Table 19: B210 Transmit Frequency Error over Temperature — Unit 2
Ambient Temperature (°C) 1 GHz (ppm) 3 GHz (ppm) 6 GHz (ppm)
-40 3 3 3.2
-30 3 4 4
-20 3 3 3
-10 2 2.3 2.5
0 2 2 2.2
10 2 2 2.2
20 2 2 2
30 2 2 1.8
40 2 2 1.8
50 2 1.7 1.8
60 2 2 1.8
70 2 1.7 1.8

Note: Measurements were performed immediately following startup using independent DUT and measurement equipment reference clocks. Additional warm-up time and a shared external reference may further improve frequency accuracy.

B206Mini-I

Device Configuration

Table 20: B206mini-I Transmit Frequency Accuracy Test Configuration
Settings RFSA SDR – B206mini-I
Hardware Configuration -- Board Only
Frequency Range 1 – 6 GHz 1 – 6 GHz
Ref Clock PXI Clock* Internal
Clock Rate 10 MS/s 61.44 MS/s

*Note: Results were also verified with VST Onboard Clock and had no significant impact on the frequency accuracy drift over temperature.

Results

Table 21: B206mini-I Transmit Frequency Error over Temperature — Unit 1
Temp (°C) 1 GHz (ppm) 3 GHz (ppm) 6 GHz (ppm)
-40 -1 -1.3 -1.2
-30 0 -0.3 -0.3
-20 0 -0.3 -0.3
-10 0 -0.3 0
0 0 -0.3 0
10 0 0 0
20 0 0 0
30 0 -0.3 -0.3
40 0 -0.3 -0.3
50 0 -0.3 -0.5
60 0 -0.3 -0.5
70 0 -0.3 -0.5
Table 22: B206mini-I Transmit Frequency Error over Temperature — Unit 2
Temp (°C) 1 GHz (ppm) 3 GHz (ppm) 6 GHz (ppm)
-40 -3 -2.7 -2.3
-30 0 0 0
-20 0 0 0.2
-10 0 0 0
0 0 0 0
10 0 0 0
20 0 0.3 0.2
30 0 0 0
40 0 0 0
50 0 0 0
60 0 -0.3 -0.2
70 0 -0.3 -0.2

Note: Measurements were performed immediately following startup using independent DUT and measurement equipment reference clocks. Additional warm-up time and a shared external reference may further improve frequency accuracy.

X310 with OBX-160 Installed

Device Configuration

Table 23: OBX-160 Installed in X310 Transmit Frequency Accuracy Test Configuration
Settings RFSA SDR – OBX-160 in X310
Frequency Range 1 – 8 GHz 1 – 8 GHz
Ref Clock PXI Clock* Internal
Clock Rate 10 MHz 200 MHz

*Note: Results were also verified with VST Onboard Clock and had no significant impact on the frequency accuracy drift over temperature.

Results

Table 24: OBX-160 Installed in X310 Transmit Frequency Error over Temperature — Unit 1
Ambient Temperature (°C) 1 GHz (ppm) 4 GHz (ppm) 8 GHz (ppm)
-40 -16 -16 -15.9
-30 -8 -7.7 -7.6
-20 -3 -3.2 -3.1
-10 -1 -0.8 -0.6
0 0 0 0
10 0 0.3 0.3
20 0 0 0
30 0 0 0
40 0 0 0
50 0 0 0
60 0 0 0
70 0 0 0.1
Table 25: OBX-160 Installed in X310 Transmit Frequency Error over Temperature — Unit 2
Ambient Temperature (°C) 1 GHz (ppm) 4 GHz (ppm) 8 GHz (ppm)
-40 9 8.5 8.5
-30 3 3 2.9
-20 2 2 1.9
-10 0 0.5 0.4
0 0 0 0.1
10 0 0.3 0.1
20 0 0 0.1
30 0 0 0.1
40 0 0 0.1
50 0 0 0.1
60 0 0 0.1
70 0 0 0

Note: Measurements were performed immediately following startup using independent DUT and measurement equipment reference clocks. Additional warm-up time and a shared external reference may further improve frequency accuracy.

X420

Device Configuration

Table 26: X420 Transmit Frequency Accuracy Test Configuration
Settings RFSA SDR – X420
Frequency Range 1 – 20 GHz 1 – 20 GHz
Ref Clock PXI Clock* Internal
Clock Rate 10 MHz 200 MHz

*Note: Results were also verified with VST Onboard Clock and had no significant impact on the frequency accuracy drift over temperature.

Note: TX Frequency Accuracy testing was performed with the default (exhaust airflow) fan configuration. Results may differ if the alternative intake airflow configuration is used.

Results

Table 27: X420 Transmit Frequency Error over Temperature — Channel 0
Ambient Temperature (°C) 1 GHz (ppm) 10 GHz (ppm) 20 GHz (ppm)
-10 0 -0.3 -0.25
0 0 -0.3 -0.25
10 0 -0.3 -0.25
20 0 -0.3 -0.25
30 0 -0.2 -0.25
40 0 -0.2 -0.25
50 0 -0.2 -0.25
60 0 -0.2 -0.25
Table 28: X420 Transmit Frequency Error over Temperature — Channel 1
Ambient Temperature (°C) 1 GHz (ppm) 10 GHz (ppm) 20 GHz (ppm)
-10 0 -0.3 -0.3
0 0 -0.3 -0.25
10 0 -0.3 -0.25
20 0 -0.3 -0.25
30 0 -0.3 -0.25
40 0 -0.2 -0.25
50 0 -0.2 -0.25
60 0 -0.2 -0.25

Note: Measurements were performed immediately following startup using independent DUT and measurement equipment reference clocks. Additional warm-up time and a shared external reference may further improve frequency accuracy.

Shock and Vibration Qualification

B210

This section describes the test configuration used to test the B210 against the listed shock and vibration specifications.

Test Configuration

The B210 test configuration was selected to represent the most common customer use case. This qualification testing focused on verifying the B210 RF functionality, unlike standard qualification testing, in which all IO is monitored. The device was installed in its enclosure accessory (NI Part Number: 784190-01) and secured to the shock and vibration test table using clamps. Each cable had strain relief near its input connection port. For operational test cases, the B210 was connected to a host and powered through its USB3 port using the USB 3.0 Type A to Type B cable supplied with the B210 kit. RF functionality was verified on both channels, RF0 and RF1, using a loopback connection from the transceiver port, TX1/RX1, to the receiver port, RX2, on each channel. Pass/fail determination was based on continuous monitoring of the received signal; any drop below the pre-determined threshold of -70 dBm, approximately 20 dB below the expected received power, constituted a failure. Testing did not qualify the B210 bare board variant or monitored the functionality of the GPS, Ref IN, and PPS IN ports. Additionally, the GPSDO (TXCO) B210 accessory (NI Part Number: 783454-01) was not installed during this testing.

B210 Shock and Vibration Hardware Configuration.png
Figure 1: B210 Shock and Vibration Hardware Configuration

Results

No failures on the B210 module were observed during the operating and non-operating Shock and Vibration Testing.

Table 29: B210 Shock and Vibration Test Results
Parameter Value Result
Operating Vibration, random 5 Hz to 500 Hz, 0.3 g RMS Pass
Non-Operating Vibration, random 5 Hz to 500 Hz, 2.4 g RMS Pass
Operating Shock 30 g peak , half-sine, 11 ms pulse Pass

This product was tested in accordance with the following environmental standards for electrical equipment:

  • IEC 60068-2-64 Broadband random vibration
  • IEC 60068-2-27 Shock

B206Mini-I

This section describes the test configuration used to test the B206mini-I against the listed shock and vibration specifications.

Test Configuration

The B206mini-I test configuration was selected to represent the most common customer use case. This qualification testing focused on verifying the B206mini-I RF functionality, unlike standard qualification testing, in which all IO is monitored. The device was installed in its enclosure (NI Part Number: 789155-01) and was secured to the shock and vibration test table using clamps. Each cable had strain relief near its input connection port. For operational test cases, the device was connected to a host and powered through the USB3 port. The RF functionality was verified using an RF loopback connection from the transceiver port, TRX, to the receiver port, RX2. Pass/fail determination was based on continuous monitoring of the received signal; any drop below the pre-determined threshold of -60dBm, approximately 15 dB below the expected received power, constituted a failure. Testing did not qualify the B206mini-I bare board variant or monitored the functionality of the GPIO and Ref Ports.

B206mini-I Shock and Vibration Hardware Configuration.png
Figure 2: B206mini-I Shock and Vibration Hardware Configuration

Results

No failures on the B206mini-I module were observed during the operating and non-operating Shock and Vibration Testing.

Table 30: B206mini-I Shock and Vibration Test Results
Parameter Value Result
Operating Vibration, random 0.3 g RMS, 5 Hz to 500 Hz Pass
5 g RMS, 10 Hz to 500 Hz Pass
Operating Vibration, sinusoidal 5 g, 10 Hz to 500 Hz Pass
Non-Operating Vibration, random 2.4 g RMS, 5 Hz to 500 Hz Pass
Operating Shock 30 g, 11 ms half-sine;
50 g, 3 ms half-sine;
18 shocks at 6 orientations
Pass

This product was tested in accordance with the following environmental standards for electrical equipment:

  • IEC 60068-2-64 Broadband random vibration
  • IEC 60068-2-6 Sinusoidal vibration
  • IEC 60068-2-27 Shock

OBX-160 Installed in USRP X310

This section describes the test configuration used to test the OBX-160 installed in the USRP X310 enclosure against the listed shock and vibration specifications.

Test Configuration

The OBX-160 test configuration was selected to represent the most common customer use case. Two OBX-160 modules (NI Part Number: 789162-01) were installed into the daughtercard slots of the USRP X310 enclosure (NI Part Number: 783145-01), which was secured to the shock and vibration test table using clamps. The USRP X310 was used for mounting purposes; The test itself does not qualify the USRP X310 against these Shock and Vibration specifications. Each cable had strain relief near its input connection port. For operational test cases, the device was powered using the standard X310 power supply and was connected to a host through a 1G Ethernet connection. The RF functionality of both OBX-160 modules was verified using an RF loopback connection from the transceiver port, TX/RX, to the receiver port, RX2. Pass/fail determination was based on continuous monitoring of the received signal; any drop below the pre-determined threshold of -70dBm, approximately 20 dB below the expected received power, constituted a failure. Testing did not qualify the OBX-160 module standalone or monitored the USRP X310 IO ports. Additionally, the GPSDO (OCXO) X310 accessory (NI Part Number: 783173-01) was not installed in the X310 during this testing. A separate test found that the GPSDO module comes loose when subjected to an 11 ms, 50 g half-sine shock in accordance with IEC 68-2-27.

OBX-160 X310 Shock and Vibration Hardware Configuration.png
Figure 3: OBX-160 Installed in X310 Shock and Vibration Hardware Configuration

Results

No failures on the OBX-160 modules were observed during the operating and non-operating Shock and Vibration Testing.

Table 31: OBX-160 Installed in X310 Shock and Vibration Test Results
Parameter Value Result
Operating Vibration, random 0.3 g RMS, 5 Hz to 500 Hz Pass
5 g RMS, 10 Hz to 500 Hz Pass
Operating Vibration, sinusoidal 5 g, 10 Hz to 500 Hz Pass
Non-Operating Vibration, random 2.4 g RMS, 5 Hz to 500 Hz Pass
Operating Shock 30 g, 11 ms half-sine;
50 g, 3 ms half-sine;
18 shocks at 6 orientations
Pass

This product was tested in accordance with the following environmental standards for electrical equipment:

  • IEC 60068-2-64 Broadband random vibration
  • IEC 60068-2-6 Sinusoidal vibration
  • IEC 60068-2-27 Shock