Difference between revisions of "Extended USRP Environmental"
DylanCaswell (Talk | contribs) m (→Shock and Vibration Qualification) |
DylanCaswell (Talk | contribs) m (→Application Note Number and Authors) |
||
| Line 9: | Line 9: | ||
== <span style="font-family:Cambria, Georgia, serif; font-size:20pt; font-weight:normal; color:#008958;">Application Note Number and Authors</span> == | == <span style="font-family:Cambria, Georgia, serif; font-size:20pt; font-weight:normal; color:#008958;">Application Note Number and Authors</span> == | ||
| − | AN-966 by Daniel Wen, Kambrey Marini | + | AN-966 by Daniel Wen, Kambrey Marini, Cole Garrison |
This document presents the results of extended environmental research on the Ettus USRP B210, B206mini-I, OBX-160 installed in the X310, and X420. The research examines RF performance beyond the official operating temperature specifications, including cold-start functionality, high-temperature stress testing, and transmit frequency accuracy. It also documents exploratory shock and vibration research conducted on the B210, B206mini-I, and OBX-160 installed in the X310, none of which had previously been tested for ruggedness. | This document presents the results of extended environmental research on the Ettus USRP B210, B206mini-I, OBX-160 installed in the X310, and X420. The research examines RF performance beyond the official operating temperature specifications, including cold-start functionality, high-temperature stress testing, and transmit frequency accuracy. It also documents exploratory shock and vibration research conducted on the B210, B206mini-I, and OBX-160 installed in the X310, none of which had previously been tested for ruggedness. | ||
Latest revision as of 15:35, 20 November 2026
Ettus USRP Extended Environmental Research Knowledge Base
Contents
Application Note Number and Authors
AN-966 by Daniel Wen, Kambrey Marini, Cole Garrison
This document presents the results of extended environmental research on the Ettus USRP B210, B206mini-I, OBX-160 installed in the X310, and X420. The research examines RF performance beyond the official operating temperature specifications, including cold-start functionality, high-temperature stress testing, and transmit frequency accuracy. It also documents exploratory shock and vibration research conducted on the B210, B206mini-I, and OBX-160 installed in the X310, none of which had previously been tested for ruggedness.
Disclaimer
This document summarizes the results of extended environmental research performed on a limited, non-statistical number of units of Ettus USRP products. The testing was conducted as an engineering research effort to better understand observed device behavior beyond published operating specifications and under the specific conditions described in this document. It is not intended to establish new product specifications, environmental ratings, or guaranteed operating limits. Official product datasheets remain the authoritative source for verified operating conditions and product specifications.
Testing was designed around common customer transmit and receive use cases and focused on verification of core RF functionality under the documented environmental conditions. Validation of all device interfaces, peripheral functions, accessories, and operating modes was outside the scope of this extended research effort. As such, successful test completion should be interpreted as verification of the tested RF functionality only.
Successful completion of the tests described in this document should not be interpreted as evidence of long-term reliability, lifetime performance, or component aging effects. Several evaluations were designed to assess functionality and short-duration operational stability only, including elevated-temperature testing conducted for approximately 30 minutes at each test condition.
RF Performance Over Temperature
Cold Start Testing
Objective
Cold-start testing was conducted to characterize device startup behavior after extended exposure to low temperatures. The purpose of this evaluation was to identify potential temperature-related limitations affecting device initialization, subsystem startup, and immediate RF operation following power application. For the purposes of this research, successful initialization and verification of a Tx/Rx loopback test were considered successful cold-start functionality.
Test Procedure
- Cold Soak the DUT until board reaches steady state at target ambient temperature
- Power on the DUT and verify initialization running the uhd_find_devices and uhd_usrp_probe command
- Execute a Tx/Rx Loopback test
- Verify basic RF functionality by adjusting Rx and Tx gain settings and confirming corresponding changes in received signal power
Scope & Considerations
B210: The B210 has a published operating temperature range of 0°C to 45°C. Cold-start testing was conducted at -40°C using the board-only configuration, representing operation 40°C below the published minimum operating temperature.
B206Mini-I: The B206mini-I board-only configuration has a published operating temperature range of 0°C to 45°C. Cold-start testing was conducted at -40°C using the board-only configuration. The enclosed variant is separately, officially specified for operation from -40°C to 75°C. The cold start testing results are consistent with the official enclosed specifications; however, they should not be interpreted as official specifications for the board only variant.
X310+OBX: The OBX-160 installed in the X310 has a published operating temperature range of 0°C to 40°C. Cold-start testing was performed at -40°C, representing operation significantly below the published specifications
X420: The X420 has a published operating temperature range of 0°C to 50°C. Cold-start testing was performed at -40°C, representing operation significantly below the published specifications
B210
Device Configuration
| Parameter | Value |
|---|---|
| Hardware Configuration | Board Only |
| RF Operation | Tx/Rx Loopback (Both Channels) |
| Center Frequency | 1 GHz |
| Sample Rate | 10 MS/s |
| Tx Gain | 40dB |
| Rx Gain | 40dB |
| External Attenuation | 60dB |
| Waveform Type | CW Tone |
Results
| DUT | Ambient Temperature (°C) | Result |
|---|---|---|
| B210 1 | -40 | Observed Functional Operation |
| B210 2 | -40 | Observed Functional Operation |
B206Mini-I
Device Configuration
| Parameter | Value |
|---|---|
| Hardware Configuration | Board Only |
| RF Operation | Tx/Rx Loopback |
| Center Frequency | 1 GHz |
| Sample Rate | 10 MS/s |
| Tx Gain | 40dB |
| Rx Gain | 40dB |
| External Attenuation | 60dB |
| Waveform Type | CW Tone |
Results
| DUT | Ambient Temperature (°C) | Result |
|---|---|---|
| B206Mini-I 1 | -40 | Observed Functional Operation |
| B206Mini-I 2 | -40 | Observed Functional Operation |
X310 with OBX-160 Installed
Device Configuration
| Parameter | Value |
|---|---|
| RF Operation | Tx/Rx Loopback (Both Channels) |
| Center Frequency | 1 GHz |
| Sample Rate | 10 MS/s |
| Tx Gain | 20dB |
| Rx Gain | 20dB |
| External Attenuation | 60dB |
| Waveform Type | CW Tone |
Results
| DUT | Ambient Temperature (°C) | Result |
|---|---|---|
| X310+OBX 1 | -40 | Observed Functional Operation |
| X310+OBX 2 | -40 | Observed Functional Operation |
X420
Device Configuration
| Parameter | Value |
|---|---|
| RF Operation | Tx/Rx Loopback (Both Channels) |
| Center Frequency | 5 GHz |
| Sample Rate | 50 MS/s |
| Tx Gain | 60dB |
| Rx Gain | 10dB |
| External Attenuation | 60dB |
| Waveform Type | CW Tone |
Results
| DUT | Ambient Temp(°C) | Recorded DB Temp (°C) | Recorded FPGA Temp (°C) | Result |
|---|---|---|---|---|
| X420 Unit 1 | -40 | Not Recorded | Not Recorded | No Functional Operation Observed |
| X420 Unit 1 | -10 | -5 | 0 | Observed Functional Operation |
Note: The temperatures shown for passing tests are the lowest temperatures at which the device successfully started and operated. Failed tests did not record a recovery temperature.
High Temperature Stress Testing
Objective
High temperature stress testing was conducted to characterize device functionality and operational stability at elevated ambient temperatures. The purpose of this evaluation was to identify potential temperature-related limitations affecting RF operation, device initialization, thermal management, and overall system stability when exposed to temperatures beyond published operating specifications.
Test Procedure
- Set chamber to the target ambient temperature and let board reach steady state
- Power on the DUT and verify initialization running the uhd_find_devices and uhd_usrp_probe command
- Verify stable operation for 0.5 Hrs. with no streaming errors, device resets, or thermal shutdown events
Scope & Considerations
High temperature stress testing was designed to evaluate functionality and short-duration operational stability under elevated ambient temperatures. Each test condition consisted of approximately 30 minutes of operation after thermal stabilization. These results do not evaluate long-term effects of the device. Successful operation during this testing characterizes the tested units and should not be interpreted as evidence of sustained performance at elevated temperatures.
FPGA Temperature Measurements: Recorded FPGA temperatures are included as an indicator of the thermal conditions experienced by the device during testing. These values provide additional context beyond ambient chamber temperature and help illustrate the thermal margin available to the FPGA under the documented test conditions. FPGA temperatures were not used as a pass/fail criterion but are provided as supplemental thermal characterization data.
B210: The B210 board-only and enclosed configurations have a published operating temperature range of 0°C to 45°C. High-temperature stress testing was conducted up to 70°C, representing operation 25°C above the published maximum operating temperature.
B206Mini-I: The B206mini-I board-only configuration has a published operating temperature range of 0°C to 45°C. High temperature testing was conducted up to 70°C for both device variants. The enclosed variant is separately, officially specified for operation from -40°C to 75°C. The board only testing results are consistent with the official enclosed specifications; however, they should not be interpreted as official specifications for the board only variant.
X310+OBX: The OBX-160 installed in the X310 has a published operating temperature range of 0°C to 40°C. High temperature testing was performed up to 70°C.
X420: The X420 has a published operating temperature range of 0°C to 50°C. High temperature testing was performed up to 70°C.
B210
Device Configuration
| Parameter | Tx | Rx |
|---|---|---|
| Center Frequency | 5 GHz | 5 GHz |
| Sampling Rate | 10 MS/s | 20 MS/s |
| Gain | 30dB | 76dB |
| External Attenuation | 30dB | 30dB |
Results
| Unit | Ambient Temperature (°C) | Recorded FPGA Temperature (°C) | Result |
|---|---|---|---|
| Board Only | 70 | Not Recorded | Observed Functional Operation |
| Normal Enclosure | 70 | 88 | Observed Functional Operation |
B206Mini-I
Device Configuration
| Parameter | Tx | Rx |
|---|---|---|
| Center Frequency | 5 GHz | 5 GHz |
| Sampling Rate | 10 MS/s | 20 MS/s |
| Gain | 30dB | 76dB |
| External Attenuation | 30dB | 30dB |
Results
| Unit | Ambient Temperature (°C) | Recorded FPGA Temperature (°C) | Result |
|---|---|---|---|
| B206mini-I Board Only | 70 | Not Recorded | Observed Functional Operation |
| B206mini-I Enclosed | 70 | 84 | Observed Functional Operation |
X310 with OBX-160 Installed
Device Configuration
| Parameter | Tx | Rx |
|---|---|---|
| Center Frequency | 5 GHz | 5 GHz |
| Sampling Rate | 50 MS/s | 200 MS/s |
| Gain | 25dB | 10dB |
| External Attenuation | 30dB | 30dB |
Results
| Unit | Ambient Temperature (°C) | Recorded FPGA Temperature (°C) | Result |
|---|---|---|---|
| X310+OBX 1 | 70 | 90.8 | Observed Functional Operation |
| X310+OBX 2 | 70 | 92.7 | Observed Functional Operation |
X420
Device Configuration
| Parameter | Tx | Rx |
|---|---|---|
| Center Frequency | 5 GHz | 5 GHz |
| Sampling Rate | 491.52 MS/s | 491.52 MS/s |
| Gain | 60dB | 10dB |
| External Attenuation | 30dB | 30dB |
Note: High-temperature stress testing was performed with the default (exhaust airflow) fan configuration. Results may differ if the alternative intake airflow configuration is used.
Results
| DUT | Ambient Temp (°C) | Recorded FPGA Temp (°C) | Recorded DB Temp (°C) | Result |
|---|---|---|---|---|
| X420 Unit 1 | 70 | Not Recorded | Not Recorded | No Functional Operation Observed |
| X420 Unit 1 | 60 | 74 | 73 | Observed Functional Operation |
Note: Recoded temperatures represent the highest observed temperatures at which the device successfully passed.
Tx Frequency Accuracy
Objective
Transmit frequency accuracy testing was conducted to characterize the startup frequency error of each device across the evaluated temperature range. The objective was to identify temperature-dependent frequency deviations immediately following initialization and to provide insight into the observed frequency stability of the tested units under the documented conditions. Frequency error was evaluated across representative frequencies for each platform and reported in parts per million (ppm)
[math]Frequency\ Error\ (ppm) = \frac{f_{measured} - f_{expected}}{f_{expected}} \times 10^{6}[/math]
Test Procedure
- Set chamber to the target ambient temperature and let board reach steady state
- Power on the DUT and verify initialization running the uhd_find_devices and uhd_usrp_probe command
- Run Tx Frequency Accuracy Sweep
Scope & Considerations
Startup Frequency Error: Frequency accuracy measurements were intentionally performed immediately following device initialization at each temperature setpoint. This approach provided a consistent methodology for evaluating frequency errors across the full temperature range and allowed direct comparison between test conditions. Because measurements were taken immediately following initialization, the reported frequency errors represent startup behavior rather than steady-state operation. Additional warm-up time, particularly at colder temperatures, may improve frequency accuracy.
Reference Clock Configuration: Frequency accuracy measurements were performed using independent reference clocks for the DUT and measurement equipment. This approach reflects a standalone operating condition and prevents shared reference clocks form influencing measured startup frequency error. In many applications, a common external reference clock may be used between systems, which can further improve frequency accuracy. The RFSA was configured to use the PXI clock during testing. To verify the selected measurement reference did not materially affect the results, spot-check validations were performed using the onboard reference clock of a PXIe-5842. No significant impact on the measured frequency error or frequency drift over temperature was observed.
Measurement Resolution and Reported Precision: Frequency error values were derived from frequency offset measurements with an effective resolution of approximately 1 kHz. The equivalent ppm resolution varies with carrier frequency, ranging from approximately 1 ppm at 1 GHz to approximately 0.05 ppm at 20 GHz. Reported values have been rounded to reflect the practical resolution limits of the measurement system to avoid implying greater precision than was achievable. Actual device performance may be better than indicated by reported values.
B210
Device Configuration
| Settings | RFSA | SDR – B210 |
|---|---|---|
| Hardware Configuration | -- | Board Only |
| Frequency Range | 1 – 6 GHz | 1 – 6 GHz |
| Ref Clock | PXI Clock* | Internal |
| Clock Rate | 10 MS/s | 61.44 MS/s |
*Note: Results were also verified with VST Onboard Clock and had no significant impact on the frequency accuracy drift over temperature.
Results
| Ambient Temperature (°C) | 1 GHz (ppm) | 3 GHz (ppm) | 6 GHz (ppm) |
|---|---|---|---|
| -40 | 4 | 3.7 | 3.7 |
| -30 | 4 | 4 | 4 |
| -20 | 3 | 2.7 | 2.8 |
| -10 | 3 | 2.7 | 2.5 |
| 0 | 2 | 2.3 | 2.3 |
| 10 | 2 | 2.3 | 2.3 |
| 20 | 2 | 2.3 | 2.3 |
| 30 | 2 | 2 | 2.2 |
| 40 | 2 | 2.3 | 2.2 |
| 50 | 2 | 2.3 | 2.2 |
| 60 | 2 | 2 | 2 |
| 70 | 2 | 2 | 2 |
| Ambient Temperature (°C) | 1 GHz (ppm) | 3 GHz (ppm) | 6 GHz (ppm) |
|---|---|---|---|
| -40 | 3 | 3 | 3.2 |
| -30 | 3 | 4 | 4 |
| -20 | 3 | 3 | 3 |
| -10 | 2 | 2.3 | 2.5 |
| 0 | 2 | 2 | 2.2 |
| 10 | 2 | 2 | 2.2 |
| 20 | 2 | 2 | 2 |
| 30 | 2 | 2 | 1.8 |
| 40 | 2 | 2 | 1.8 |
| 50 | 2 | 1.7 | 1.8 |
| 60 | 2 | 2 | 1.8 |
| 70 | 2 | 1.7 | 1.8 |
Note: Measurements were performed immediately following startup using independent DUT and measurement equipment reference clocks. Additional warm-up time and a shared external reference may further improve frequency accuracy.
B206Mini-I
Device Configuration
| Settings | RFSA | SDR – B206mini-I |
|---|---|---|
| Hardware Configuration | -- | Board Only |
| Frequency Range | 1 – 6 GHz | 1 – 6 GHz |
| Ref Clock | PXI Clock* | Internal |
| Clock Rate | 10 MS/s | 61.44 MS/s |
*Note: Results were also verified with VST Onboard Clock and had no significant impact on the frequency accuracy drift over temperature.
Results
| Temp (°C) | 1 GHz (ppm) | 3 GHz (ppm) | 6 GHz (ppm) |
|---|---|---|---|
| -40 | -1 | -1.3 | -1.2 |
| -30 | 0 | -0.3 | -0.3 |
| -20 | 0 | -0.3 | -0.3 |
| -10 | 0 | -0.3 | 0 |
| 0 | 0 | -0.3 | 0 |
| 10 | 0 | 0 | 0 |
| 20 | 0 | 0 | 0 |
| 30 | 0 | -0.3 | -0.3 |
| 40 | 0 | -0.3 | -0.3 |
| 50 | 0 | -0.3 | -0.5 |
| 60 | 0 | -0.3 | -0.5 |
| 70 | 0 | -0.3 | -0.5 |
| Temp (°C) | 1 GHz (ppm) | 3 GHz (ppm) | 6 GHz (ppm) |
|---|---|---|---|
| -40 | -3 | -2.7 | -2.3 |
| -30 | 0 | 0 | 0 |
| -20 | 0 | 0 | 0.2 |
| -10 | 0 | 0 | 0 |
| 0 | 0 | 0 | 0 |
| 10 | 0 | 0 | 0 |
| 20 | 0 | 0.3 | 0.2 |
| 30 | 0 | 0 | 0 |
| 40 | 0 | 0 | 0 |
| 50 | 0 | 0 | 0 |
| 60 | 0 | -0.3 | -0.2 |
| 70 | 0 | -0.3 | -0.2 |
Note: Measurements were performed immediately following startup using independent DUT and measurement equipment reference clocks. Additional warm-up time and a shared external reference may further improve frequency accuracy.
X310 with OBX-160 Installed
Device Configuration
| Settings | RFSA | SDR – OBX-160 in X310 |
|---|---|---|
| Frequency Range | 1 – 8 GHz | 1 – 8 GHz |
| Ref Clock | PXI Clock* | Internal |
| Clock Rate | 10 MHz | 200 MHz |
*Note: Results were also verified with VST Onboard Clock and had no significant impact on the frequency accuracy drift over temperature.
Results
| Ambient Temperature (°C) | 1 GHz (ppm) | 4 GHz (ppm) | 8 GHz (ppm) |
|---|---|---|---|
| -40 | -16 | -16 | -15.9 |
| -30 | -8 | -7.7 | -7.6 |
| -20 | -3 | -3.2 | -3.1 |
| -10 | -1 | -0.8 | -0.6 |
| 0 | 0 | 0 | 0 |
| 10 | 0 | 0.3 | 0.3 |
| 20 | 0 | 0 | 0 |
| 30 | 0 | 0 | 0 |
| 40 | 0 | 0 | 0 |
| 50 | 0 | 0 | 0 |
| 60 | 0 | 0 | 0 |
| 70 | 0 | 0 | 0.1 |
| Ambient Temperature (°C) | 1 GHz (ppm) | 4 GHz (ppm) | 8 GHz (ppm) |
|---|---|---|---|
| -40 | 9 | 8.5 | 8.5 |
| -30 | 3 | 3 | 2.9 |
| -20 | 2 | 2 | 1.9 |
| -10 | 0 | 0.5 | 0.4 |
| 0 | 0 | 0 | 0.1 |
| 10 | 0 | 0.3 | 0.1 |
| 20 | 0 | 0 | 0.1 |
| 30 | 0 | 0 | 0.1 |
| 40 | 0 | 0 | 0.1 |
| 50 | 0 | 0 | 0.1 |
| 60 | 0 | 0 | 0.1 |
| 70 | 0 | 0 | 0 |
Note: Measurements were performed immediately following startup using independent DUT and measurement equipment reference clocks. Additional warm-up time and a shared external reference may further improve frequency accuracy.
X420
Device Configuration
| Settings | RFSA | SDR – X420 |
|---|---|---|
| Frequency Range | 1 – 20 GHz | 1 – 20 GHz |
| Ref Clock | PXI Clock* | Internal |
| Clock Rate | 10 MHz | 200 MHz |
*Note: Results were also verified with VST Onboard Clock and had no significant impact on the frequency accuracy drift over temperature.
Note: TX Frequency Accuracy testing was performed with the default (exhaust airflow) fan configuration. Results may differ if the alternative intake airflow configuration is used.
Results
| Ambient Temperature (°C) | 1 GHz (ppm) | 10 GHz (ppm) | 20 GHz (ppm) |
|---|---|---|---|
| -10 | 0 | -0.3 | -0.25 |
| 0 | 0 | -0.3 | -0.25 |
| 10 | 0 | -0.3 | -0.25 |
| 20 | 0 | -0.3 | -0.25 |
| 30 | 0 | -0.2 | -0.25 |
| 40 | 0 | -0.2 | -0.25 |
| 50 | 0 | -0.2 | -0.25 |
| 60 | 0 | -0.2 | -0.25 |
| Ambient Temperature (°C) | 1 GHz (ppm) | 10 GHz (ppm) | 20 GHz (ppm) |
|---|---|---|---|
| -10 | 0 | -0.3 | -0.3 |
| 0 | 0 | -0.3 | -0.25 |
| 10 | 0 | -0.3 | -0.25 |
| 20 | 0 | -0.3 | -0.25 |
| 30 | 0 | -0.3 | -0.25 |
| 40 | 0 | -0.2 | -0.25 |
| 50 | 0 | -0.2 | -0.25 |
| 60 | 0 | -0.2 | -0.25 |
Note: Measurements were performed immediately following startup using independent DUT and measurement equipment reference clocks. Additional warm-up time and a shared external reference may further improve frequency accuracy.
Shock and Vibration Qualification
B210
This section describes the test configuration used to test the B210 against the listed shock and vibration specifications.
Test Configuration
The B210 test configuration was selected to represent the most common customer use case. This qualification testing focused on verifying the B210 RF functionality, unlike standard qualification testing, in which all IO is monitored. The device was installed in its enclosure accessory (NI Part Number: 784190-01) and secured to the shock and vibration test table using clamps. Each cable had strain relief near its input connection port. For operational test cases, the B210 was connected to a host and powered through its USB3 port using the USB 3.0 Type A to Type B cable supplied with the B210 kit. RF functionality was verified on both channels, RF0 and RF1, using a loopback connection from the transceiver port, TX1/RX1, to the receiver port, RX2, on each channel. Pass/fail determination was based on continuous monitoring of the received signal; any drop below the pre-determined threshold of -70 dBm, approximately 20 dB below the expected received power, constituted a failure. Testing did not qualify the B210 bare board variant or monitored the functionality of the GPS, Ref IN, and PPS IN ports. Additionally, the GPSDO (TXCO) B210 accessory (NI Part Number: 783454-01) was not installed during this testing.
Results
No failures on the B210 module were observed during the operating and non-operating Shock and Vibration Testing.
| Parameter | Value | Result |
|---|---|---|
| Operating Vibration, random | 5 Hz to 500 Hz, 0.3 g RMS | Pass |
| Non-Operating Vibration, random | 5 Hz to 500 Hz, 2.4 g RMS | Pass |
| Operating Shock | 30 g peak , half-sine, 11 ms pulse | Pass |
This product was tested in accordance with the following environmental standards for electrical equipment:
- IEC 60068-2-64 Broadband random vibration
- IEC 60068-2-27 Shock
B206Mini-I
This section describes the test configuration used to test the B206mini-I against the listed shock and vibration specifications.
Test Configuration
The B206mini-I test configuration was selected to represent the most common customer use case. This qualification testing focused on verifying the B206mini-I RF functionality, unlike standard qualification testing, in which all IO is monitored. The device was installed in its enclosure (NI Part Number: 789155-01) and was secured to the shock and vibration test table using clamps. Each cable had strain relief near its input connection port. For operational test cases, the device was connected to a host and powered through the USB3 port. The RF functionality was verified using an RF loopback connection from the transceiver port, TRX, to the receiver port, RX2. Pass/fail determination was based on continuous monitoring of the received signal; any drop below the pre-determined threshold of -60dBm, approximately 15 dB below the expected received power, constituted a failure. Testing did not qualify the B206mini-I bare board variant or monitored the functionality of the GPIO and Ref Ports.
Results
No failures on the B206mini-I module were observed during the operating and non-operating Shock and Vibration Testing.
| Parameter | Value | Result |
|---|---|---|
| Operating Vibration, random | 0.3 g RMS, 5 Hz to 500 Hz | Pass |
| 5 g RMS, 10 Hz to 500 Hz | Pass | |
| Operating Vibration, sinusoidal | 5 g, 10 Hz to 500 Hz | Pass |
| Non-Operating Vibration, random | 2.4 g RMS, 5 Hz to 500 Hz | Pass |
| Operating Shock | 30 g, 11 ms half-sine; 50 g, 3 ms half-sine; 18 shocks at 6 orientations |
Pass |
This product was tested in accordance with the following environmental standards for electrical equipment:
- IEC 60068-2-64 Broadband random vibration
- IEC 60068-2-6 Sinusoidal vibration
- IEC 60068-2-27 Shock
OBX-160 Installed in USRP X310
This section describes the test configuration used to test the OBX-160 installed in the USRP X310 enclosure against the listed shock and vibration specifications.
Test Configuration
The OBX-160 test configuration was selected to represent the most common customer use case. Two OBX-160 modules (NI Part Number: 789162-01) were installed into the daughtercard slots of the USRP X310 enclosure (NI Part Number: 783145-01), which was secured to the shock and vibration test table using clamps. The USRP X310 was used for mounting purposes; The test itself does not qualify the USRP X310 against these Shock and Vibration specifications. Each cable had strain relief near its input connection port. For operational test cases, the device was powered using the standard X310 power supply and was connected to a host through a 1G Ethernet connection. The RF functionality of both OBX-160 modules was verified using an RF loopback connection from the transceiver port, TX/RX, to the receiver port, RX2. Pass/fail determination was based on continuous monitoring of the received signal; any drop below the pre-determined threshold of -70dBm, approximately 20 dB below the expected received power, constituted a failure. Testing did not qualify the OBX-160 module standalone or monitored the USRP X310 IO ports. Additionally, the GPSDO (OCXO) X310 accessory (NI Part Number: 783173-01) was not installed in the X310 during this testing. A separate test found that the GPSDO module comes loose when subjected to an 11 ms, 50 g half-sine shock in accordance with IEC 68-2-27.
Results
No failures on the OBX-160 modules were observed during the operating and non-operating Shock and Vibration Testing.
| Parameter | Value | Result |
|---|---|---|
| Operating Vibration, random | 0.3 g RMS, 5 Hz to 500 Hz | Pass |
| 5 g RMS, 10 Hz to 500 Hz | Pass | |
| Operating Vibration, sinusoidal | 5 g, 10 Hz to 500 Hz | Pass |
| Non-Operating Vibration, random | 2.4 g RMS, 5 Hz to 500 Hz | Pass |
| Operating Shock | 30 g, 11 ms half-sine; 50 g, 3 ms half-sine; 18 shocks at 6 orientations |
Pass |
This product was tested in accordance with the following environmental standards for electrical equipment:
- IEC 60068-2-64 Broadband random vibration
- IEC 60068-2-6 Sinusoidal vibration
- IEC 60068-2-27 Shock